What a well record is
A Michigan well record, usually called a well log, is the drilling contractor's account of how a well was built: where it is, how deep it goes, what the drill passed through, how much casing was set and where the water stood when the work was done. It is a construction record, accurate about the day the rig left the property and silent about everything since.
The duty to produce it is statutory. Under the Public Health Code, the well drilling contractor must provide the owner with a copy of the record no later than 60 days after the well is completed, and file copies with the state or the local health department. The construction itself is governed by the Michigan Water Well Construction and Pump Installation Code, which is Part 127 of the Public Health Code together with administrative rules beginning at R 325.1601. The log is the paper trail of that code being applied to one hole in the ground.
The volume is large. Michigan's Governor's office has stated, in its 2025 Private Residential Well Awareness Day proclamation, that approximately 15,000 new residential wells are drilled in the state each year, and EGLE (the Michigan Department of Environment, Great Lakes, and Energy) describes contractors submitting roughly 12,000 to 14,000 new records a year.
The fields, one at a time
The statute lists the minimum contents: the owner's name, the well's location, its depth, the geologic materials and their thicknesses, the amount of casing and the static water levels. The state's standard form adds further fields under the construction rules. Each one answers a specific, narrow question.
Location
Older logs locate the well by county, township, town and range, and section, sometimes with a street address. Records filed in the state's Wellogic database since 2000 also carry latitude and longitude. Location is the field most often wrong or vague on older records, and it is the field a reader relies on to decide that a log belongs to this house.
Well depth
The total depth drilled, in feet. Depth says where the well draws water from on the day it was finished. It does not say whether the well has since been deepened, replaced or partially filled.
Casing
Casing is the steel or plastic pipe that lines the borehole and keeps surface water and loose material out. The log records its length and diameter, and on most modern logs the type of screen (a slotted section at the bottom that lets water in) and the grouting (sealing material placed around the casing). These fields show what was installed, not whether it remains intact.
Static water level
The static water level is the depth from the ground surface to the water inside the well when no pump is running. It is a measurement taken on one day, usually the day of completion. Water levels change with season, drought and nearby pumping, so an old figure is a historical reading rather than a current one.
Geology log
The driller lists the materials passed through, layer by layer, with thicknesses: topsoil, sand, gravel, clay, hardpan and so on. Northern Michigan's glacial deposits make these logs varied even between neighboring lots. The log records what the driller observed in the cuttings; it is the driller's description, not a laboratory analysis.
Pumping test, pump and water sample fields
Many logs include a short pumping test (a yield figure in gallons per minute over a stated time), the pump type and setting depth, and a note that a water sample was taken. Michigan requires a coliform bacteria test when a well is installed or repaired, so a new log is often accompanied by that first result. The yield and the sample describe the well at completion only.
Where to find the record
Where a log is kept depends on when the well was drilled. According to EGLE's Wellogic FAQ, Wellogic is primarily well records from 2000 and newer, and 80 to 85 percent of records are submitted directly into it by contractors. For wells installed in 1999 or earlier, EGLE points to its Scanned Water Well Records collection, which is searched by county, township, town and range, and section rather than by address. EGLE also notes that local health departments sometimes have well records that the state does not.
- Drilled 2000 or later: look first in Wellogic, which also holds pump-installation records and records of abandoned wells that were plugged.
- Drilled 1999 or earlier: look in the scanned records by legal description, then at the local health department, which for Wexford County is District Health Department #10.
- No record found: many older northern Michigan wells predate both systems or were never filed. A missing log is common and, by itself, establishes nothing about the well.
What a well record does not establish
A well record does not establish anything about the water today. It is not a water quality report, and the single sample taken at completion describes that day's water only. It does not establish that the pump, pressure tank, well cap or wiring are the ones installed at the time, or that they work. It does not establish the well's current yield or water level.
Most importantly, a log does not by itself establish that the well it describes is the well now serving the house. A replacement well produces a new log, and the old well should produce a plugging record. If only one log is found, it may describe a well that has since been abandoned. Private residential wells are not regulated under the Michigan Safe Drinking Water Act, so after construction nobody is required to update the file.
Where it is commonly misread
The most common misreading is matching. A reader searches by road name, finds a log for a well nearby and assumes it belongs to the house. On older records, where location is given by section rather than address, two neighboring lots can produce similar-looking logs. Some fields that would settle the question, such as the parcel's tax number and the permit number, are optional on the state's record, so they are often blank.
The second misreading is age. A reader sees a deep well with a long casing on a 1970s log and treats those figures as a description of the present well. They describe the well as built. Repairs, pump replacements and deepening may have produced records of their own, or none.
The third is treating the completion water sample as a current water test. The sample required at installation shows the water on that day, often decades ago.
Reading the log alongside the rest of the file
The well log is most useful read together with the other records in the water family. The septic permit shows where the drainfield was placed and is the place to look for distances between the two systems as designed. A recent water test shows what one sample contained. A well and septic evaluation, where one exists, records what an evaluator observed on a visit. The log supplies the construction facts the others assume.
The statute that creates the record, MCL 333.12707, is short and worth reading in full, and EGLE's water well construction program page names the code the driller was working under. This site does not interpret any individual well log.